Endothelial Dysfunction Expressed as Endothelial Microparticles in Patients With End-Stage Heart Failure

Publication at First Faculty of Medicine |
2014

Abstract

Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage.

Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD.

Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation we observed significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p= 0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n= 18) and with heart failure of non-ischemic etiology (n = 12).

In addition, heart failure etiology had no effect on the rate of EMP concentration decrease with time. These results indicate possibility that LVAD do not cause vascular damage 3 months after implantation.

Whether these results suggest improvement of vascular wall function and of endothelium is to be proved in long-term studies.