Tento text není v aktuálním jazyce dostupný. Zobrazuje se verze "en".Abstrakt

This work is focused on the development of new differential pulse voltammetric (DPV) method for the determination of submicromolar concentrations of 2-nitrophenol using carbon film electrode. The highest and the best developed DPV peak was obtained using Britton-Robinson buffer of pH = 6.0.

The best repeatability was obtained by inserting regeneration potentials E-in = 1300 mV; E-fin = 0 mV. The calibration curves of 2-nitrophenol in both deionized and drinking water were linear in the concentration range from 4x10(-7) to 1x10(-4) mol L.