Introduction: Minimally invasive pyeloplasty (MIP) for ureteropelvic junction (UPJ) obstruction in children has gained popularity over the past decade as an alternative to open surgery. The present study aimed to identify the factors affecting complication rates of MIP in children, and to compare the outcomes of laparoscopic (LP) and robotic-assisted laparoscopic pyeloplasty (RALP).
Materials and methods: The perioperative data of 783 pediatric patients (<18 years old) from 15 academic centers who underwent either LP or RALP with an Anderson Hynes dismembered pyeloplasty technique were retrospectively evaluated. Redo cases and patients with anatomic renal abnormalities were excluded.
Demographics and operative data, including procedural factors, were collected. Complications were classified according to the Satava and modified Clavien systems.
Failure was defined as any of the following: obstructive parameters on diuretic renal scintigraphy, decline in renal function, progressive hydronephrosis, or symptom relapse. Univariate and multivariate analysis were applied to identify factors affecting the complication rates.
All parameters were compared between LP and RALP.