Sixty-three heart transplant recipients were included into the study. Hundred and eighty-five endomyocardial biopsies (EMB) obtained up to 6 months after transplantation were retrospectively analyzed for signs of cellular (CR) and antibody-mediated rejection (AMR).
Pre- and post-transplant sera were tested for HGF concentrations and antibodies to HLA class I, class II and MICA antigens by xMap technology (Luminex). Pre-transplant HGF did not correlate with the incidence of CR or AMR.
However, higher HGF concentrations correlated significantly with HLA antibody production before and after transplantation (P = 0.006 and P < 0.0001 respectively). Patients with both HLA class I and class II antibodies before transplantation had significantly lower AMR-free survival.
Furthermore, recipients with pre-transplant donor-specific antibodies (DSA) had significantly lower AMR-free survival (50%) than recipients without pre-transplant HLA antibodies (90%) and patients with antibodies not specific to donor antigens (92%) (P = 0.005). Post-transplant MICA antibodies tended to be more frequent in patients with AMR (P = 0.063).
In conclusion, elevated HGF concentrations in our study were not associated with the incidence of CR and/or AMR but with the presence of HLA-specific antibodies. Testing for DSA before heart transplantation by Luminex may be helpful for the identification of patients with increased risk of AMR.